{"id":1268,"date":"2019-08-29T11:36:39","date_gmt":"2019-08-29T15:36:39","guid":{"rendered":"https:\/\/www2.whoi.edu\/site\/itp\/?page_id=1268"},"modified":"2021-07-20T11:47:58","modified_gmt":"2021-07-20T15:47:58","slug":"itp-11-data-processing","status":"publish","type":"page","link":"https:\/\/www2.whoi.edu\/site\/itp\/data\/completed-missions\/itp-11\/itp-11-data-processing\/","title":{"rendered":"ITP 011 Data Processing"},"content":{"rendered":"\r\n\t<h1>ITP 11 Data Processing<\/h1>\r\n\t<p>The 1690 profile attempts that were transmitted from the ITP were processed according to the procedures described in the\u00a0<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/ITP_Data_Processing_Procedures_35803-1.pdf\">ITP Data Processing Procedures<\/a>.\u00a0 The processing parameters (described in\u00a0<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/ITP_Data_Processing_Procedures_35803-1.pdf\">ITP Data Processing Procedures<\/a>) for ITP 11 are shown in the figures to the right.\u00a0 Thermohaline staircases were not prominent in the time series, but sufficient to sometimes compute lags which did not seem to vary (where steps were present) throughout.\u00a0 A step shift in conductivity occurred between profiles 407-429.\u00a0 \u00a0\u00a0Numerous profiles between 1060 and 1270 have odd T-S shapes above and through the Atlantic Water layer, but are stable in density.\u00a0 These profiles have some characteristics that differ from typical fouled sensor data and could portray horizontal seawater intrusions, so were not removed.\u00a0 The mooring likely dragged on the Chukchi shelf between profile 1638 and 1650, and the profiler recovered somewhat afterwards obtaining partial profiles (in higher drift speeds) up to profile 1686, when the battery rapidly exhausted.\u00a0 Due to the software overflow bug, ITP 11 experienced 68 resets with complete loss of data for these profiles, and typically incomplete vertical coverage for the next subsequent profiles.<\/p>\r\n<p>See the Data Products tab to the left for descriptions of the three levels (I, II, III) of data processing and to access all data.<\/p>\r\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp11loc2_131778.jpg\" target=\"_self\" rel=\"noopener noreferrer\">\r\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp11loc2_131778.jpg\" alt=\"ITP surface buoy status\" height=\"1730\" width=\"1000\" title=\"itp11loc2_131778\" \/>\r\n\t\t\t\t<\/a>\r\n\t\tITP surface buoy status\r\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp11dat1_131793.jpg\" target=\"_self\" rel=\"noopener noreferrer\">\r\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp11dat1_131793.jpg\" alt=\"ITP profiler engineering data\" height=\"1480\" width=\"1560\" title=\"itp11dat1_131793\" \/>\r\n\t\t\t\t<\/a>\r\n\t\tITP profiler engineering data\r\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp11final1_131993.jpg\" target=\"_self\" rel=\"noopener noreferrer\">\r\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp11final1_131993.jpg\" alt=\"Data\" height=\"3300\" width=\"2550\" title=\"itp11final1_131993\" \/>\r\n\t\t\t\t<\/a>\r\n\t\tNumber of bad points removed (top); variance of verticle difference of temperature and salinity in step region for up-going profiles; depth of staircase layer; temperature lag (bottom).\r\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp11final2_131934.jpg\" target=\"_self\" rel=\"noopener noreferrer\">\r\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp11final2_131934.jpg\" alt=\"Data\" height=\"3300\" width=\"2550\" title=\"itp11final2_131934\" \/>\r\n\t\t\t\t<\/a>\r\n\t\tTop: conductivity lag. Middle: conductivity thermal mass amplitude correction, Bottom: conductivity thermal mass lag correction.\r\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp11final3_131954.jpg\" target=\"_self\" rel=\"noopener noreferrer\">\r\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp11final3_131954.jpg\" alt=\"Top: down pressure deviation correction, Middle: salinity ratio adjustment, Bottom: Number of filtered spikes.\" height=\"3300\" width=\"2550\" title=\"itp11final3_131954\" \/>\r\n\t\t\t\t<\/a>\r\n\t\tTop: down pressure deviation correction, Middle: salinity ratio adjustment, Bottom: Number of filtered spikes.\r\n","protected":false},"excerpt":{"rendered":"<p>ITP 11 Data Processing The 1690 profile attempts that were transmitted from the ITP were processed according to the procedures described in the\u00a0ITP Data Processing Procedures.\u00a0 The processing parameters (described in\u00a0ITP Data Processing Procedures) for ITP 11 are shown in the figures to the right.\u00a0 Thermohaline staircases were not prominent in the time series, but&hellip;<\/p>\n","protected":false},"author":83,"featured_media":0,"parent":1255,"menu_order":2,"comment_status":"closed","ping_status":"closed","template":"tpl-sidebar.php","meta":{"advanced-sidebar-menu\/link-title":"","advanced-sidebar-menu\/exclude-page":false},"_links":{"self":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/1268"}],"collection":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/users\/83"}],"replies":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/comments?post=1268"}],"version-history":[{"count":3,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/1268\/revisions"}],"predecessor-version":[{"id":3443,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/1268\/revisions\/3443"}],"up":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/1255"}],"wp:attachment":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/media?parent=1268"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}