{"id":1465,"date":"2019-08-30T08:27:06","date_gmt":"2019-08-30T12:27:06","guid":{"rendered":"https:\/\/www2.whoi.edu\/site\/itp\/?page_id=1465"},"modified":"2022-03-22T16:04:24","modified_gmt":"2022-03-22T20:04:24","slug":"itp17-final-data","status":"publish","type":"page","link":"https:\/\/www2.whoi.edu\/site\/itp\/data\/completed-missions\/itp-17\/itp17-final-data\/","title":{"rendered":"ITP 017 Final Data"},"content":{"rendered":"\n\n\t<h1>ITP17 Data Description<\/h1>\n\t<p>In the surface package, the GPS receiver was powered hourly to obtain locations, and buoy temperature and battery voltage status were recorded.\u00a0 The profiler appears to have suffered from weight gain after deployment, presumably due to a small leak.\u00a0 The up profile motor currents steadily increased, while the down profile motor currents steadily decreased, suggesting that the package was getting heavier.\u00a0 Over the second 20 day period, the profiler also began the profiles in both directions 20-40 m deeper than expected (likely due to the instrument sinking on the wire before starting the next profile).\u00a0 After 36 days the ITP profiler stopped profiling (battery voltage went low), but the surface package continued to transmit GPS locations and status for a total of 652 days (with a 194 day gap in locations from January to June 2008).<\/p>\n<p>The plots to the right are of the final, calibrated, edited data (as opposed to the raw data presented on the active instrument pages).<\/p>\n<p>See the Data Products tab to the left for descriptions of the three levels (I, II, III) of data processing and to access all data.<\/p>\n\n\n\nLevel III 1-db bin-averaged processed profile data in MATLAB format:\u00a0<a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itp17final.mat\">itp17final.mat<\/a><br \/>\nLevel III 1-db bin-averaged processed profile data in ASCII format:\u00a0<a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itp17final.tar.Z\">itp17final.tar.Z<\/a> and\u00a0<a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itp17final.zip\">itp17final.zip<\/a>\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp17loc1f_259502.jpg\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp17loc1f_259502.jpg\" alt=\"Plot of buoy locations.\" height=\"1330\" width=\"800\" title=\"itp17loc1f_259502\" \/>\n\t\t\t\t<\/a>\n\t\tPlot of buoy locations.\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp17dat3f_259793.jpg\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp17dat3f_259793.jpg\" alt=\"ITP17 temperature and salinity contours\" height=\"1570\" width=\"1070\" title=\"itp17dat3f_259793\" \/>\n\t\t\t\t<\/a>\n\t\tITP17 temperature and salinity contours\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp17dat2f_259795.jpg\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp17dat2f_259795.jpg\" alt=\"Composite plot of ITP temperature and salinity contours.\" height=\"1300\" width=\"1100\" title=\"itp17dat2f_259795\" \/>\n\t\t\t\t<\/a>\n\t\tComposite plot of ITP temperature and salinity contours.\n\n","protected":false},"excerpt":{"rendered":"<p>ITP17 Data Description In the surface package, the GPS receiver was powered hourly to obtain locations, and buoy temperature and battery voltage status were recorded.\u00a0 The profiler appears to have suffered from weight gain after deployment, presumably due to a small leak.\u00a0 The up profile motor currents steadily increased, while the down profile motor currents&hellip;<\/p>\n","protected":false},"author":83,"featured_media":0,"parent":1437,"menu_order":3,"comment_status":"closed","ping_status":"closed","template":"tpl-sidebar.php","meta":{"advanced-sidebar-menu\/link-title":"","advanced-sidebar-menu\/exclude-page":false},"_links":{"self":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/1465"}],"collection":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/users\/83"}],"replies":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/comments?post=1465"}],"version-history":[{"count":3,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/1465\/revisions"}],"predecessor-version":[{"id":4049,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/1465\/revisions\/4049"}],"up":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/1437"}],"wp:attachment":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/media?parent=1465"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}