{"id":1488,"date":"2019-08-30T09:04:44","date_gmt":"2019-08-30T13:04:44","guid":{"rendered":"https:\/\/www2.whoi.edu\/site\/itp\/?page_id=1488"},"modified":"2021-07-20T12:06:09","modified_gmt":"2021-07-20T16:06:09","slug":"itp-18-data-processing","status":"publish","type":"page","link":"https:\/\/www2.whoi.edu\/site\/itp\/data\/completed-missions\/itp-18\/itp-18-data-processing\/","title":{"rendered":"ITP 018 Data Processing"},"content":{"rendered":"\r\n\t<h1>ITP18 Data Processing<\/h1>\r\n\t<p>The 912 profiles that were recovered from the ITP were processed according to the procedures described in the\u00a0<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/ITP_Data_Processing_Procedures_35803-1.pdf\">ITP Updated Data Processing Procedures<\/a>.\u00a0 The processing parameters for ITP 18 are shown in the figures to the right.\u00a0 From profile 815 to the end, the surface package was likely in marginal ice zone conditions or open water, and the vertical motion due to surface waves caused the profiler to settle at its neutrally buoyant depth between profiles, and produce either up or down half-profiles.\u00a0 Ice motion was not too great, as to prevent profiling due to drag.\u00a0 Forty-five profiles were interrupted due to the profiler software reset error.\u00a0 Some staircases were present frequently throughout the time series so sensor lags could be estimated.\u00a0 The CTD lags were in the typical range as previous systems and displayed only small amounts of drift over the year, while icing or bio-fouling instances were rare.<\/p>\r\n<p>See the Data Products tab to the left for descriptions of the three levels (I, II, III) of data processing and to access all data.<\/p>\r\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp18final1_259699.jpg\" target=\"_self\" rel=\"noopener noreferrer\">\r\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp18final1_259699.jpg\" alt=\"ITP Surface Buoy Status\" height=\"1730\" width=\"1000\" title=\"itp18final1_259699\" \/>\r\n\t\t\t\t<\/a>\r\n\t\tITP Surface Buoy Status\r\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp18dat1_259583.jpg\" target=\"_self\" rel=\"noopener noreferrer\">\r\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp18dat1_259583.jpg\" alt=\"ITP profiler engineering data.\" height=\"1480\" width=\"1560\" title=\"itp18dat1_259583\" \/>\r\n\t\t\t\t<\/a>\r\n\t\tITP profiler engineering data.\r\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp18final1_259674.jpg\" target=\"_self\" rel=\"noopener noreferrer\">\r\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp18final1_259674.jpg\" alt=\"Data\" height=\"2718\" width=\"2049\" title=\"itp18final1_259674\" \/>\r\n\t\t\t\t<\/a>\r\n\t\tTop: number of bad points removed, Middle: variance of verticle difference of temperature and salinity in step region for up-going profiles, Bottom: temperature lag.\r\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp18final2_259717.jpg\" target=\"_self\" rel=\"noopener noreferrer\">\r\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp18final2_259717.jpg\" alt=\"Data\" height=\"2745\" width=\"2046\" title=\"itp18final2_259717\" \/>\r\n\t\t\t\t<\/a>\r\n\t\tTop: conductivity lag, Middle: conductivity thermal mass amplitude correction, Bottom: conductivity thermal mass lag correction\r\n","protected":false},"excerpt":{"rendered":"<p>ITP18 Data Processing The 912 profiles that were recovered from the ITP were processed according to the procedures described in the\u00a0ITP Updated Data Processing Procedures.\u00a0 The processing parameters for ITP 18 are shown in the figures to the right.\u00a0 From profile 815 to the end, the surface package was likely in marginal ice zone conditions&hellip;<\/p>\n","protected":false},"author":83,"featured_media":0,"parent":1472,"menu_order":2,"comment_status":"closed","ping_status":"closed","template":"tpl-sidebar.php","meta":{"advanced-sidebar-menu\/link-title":"","advanced-sidebar-menu\/exclude-page":false},"_links":{"self":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/1488"}],"collection":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/users\/83"}],"replies":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/comments?post=1488"}],"version-history":[{"count":3,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/1488\/revisions"}],"predecessor-version":[{"id":3473,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/1488\/revisions\/3473"}],"up":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/1472"}],"wp:attachment":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/media?parent=1488"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}