{"id":1609,"date":"2019-08-30T14:36:12","date_gmt":"2019-08-30T18:36:12","guid":{"rendered":"https:\/\/www2.whoi.edu\/site\/itp\/?page_id=1609"},"modified":"2021-07-20T12:19:50","modified_gmt":"2021-07-20T16:19:50","slug":"itp-22-data-processing","status":"publish","type":"page","link":"https:\/\/www2.whoi.edu\/site\/itp\/data\/completed-missions\/itp-22\/itp-22-data-processing\/","title":{"rendered":"ITP 022 Data Processing"},"content":{"rendered":"\r\n\t<h1>ITP22 Data Processing<\/h1>\r\n\t<p>The 14 profiles that were recovered from the ITP were processed according to the procedures described in the\u00a0<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/ITP_Data_Processing_Procedures_35803-1.pdf\">ITP Updated Data Processing Procedures<\/a>.\u00a0 The processing parameters for ITP 22 are shown in the figures to the right.\u00a0 Despite successful test communications with the profiler on the ice, nothing was heard afterwards from the profiler for the first six weeks until September 20 when the surface package received a ring from the profiler and 14 stored profiles were recovered. \u00a0No other rings from the profiler were ever received.\u00a0 The small amount of CTD data that was received was excellent quality, but of short duration.<\/p>\r\n<p>See the Data Products tab to the left for descriptions of the three levels (I, II, III) of data processing and to access all data.<\/p>\r\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp22final1_261573.jpg\" target=\"_self\" rel=\"noopener noreferrer\">\r\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp22final1_261573.jpg\" alt=\"ITP Surface Buoy Status\" height=\"1730\" width=\"1000\" title=\"itp22final1_261573\" \/>\r\n\t\t\t\t<\/a>\r\n\t\tITP Surface Buoy Status\r\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp22dat1_261497.jpg\" target=\"_self\" rel=\"noopener noreferrer\">\r\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp22dat1_261497.jpg\" alt=\"ITP profiler engineering data.\" height=\"1480\" width=\"1560\" title=\"itp22dat1_261497\" \/>\r\n\t\t\t\t<\/a>\r\n\t\tITP profiler engineering data.\r\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp22final1_261477.jpg\" target=\"_self\" rel=\"noopener noreferrer\">\r\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp22final1_261477.jpg\" alt=\"Data\" height=\"5543\" width=\"4191\" title=\"itp22final1_261477\" \/>\r\n\t\t\t\t<\/a>\r\n\t\tTop: number of bad points removed, Middle: variance of verticle difference of temperature and salinity in step region for up-going profiles, Bottom: temperature lag.\r\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp22final2_261593.jpg\" target=\"_self\" rel=\"noopener noreferrer\">\r\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp22final2_261593.jpg\" alt=\"Data\" height=\"5459\" width=\"4090\" title=\"itp22final2_261593\" \/>\r\n\t\t\t\t<\/a>\r\n\t\tTop: conductivity lag, Middle: conductivity thermal mass amplitude correction, Bottom: conductivity thermal mass lag correction\r\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp22final3_261535.jpg\" target=\"_self\" rel=\"noopener noreferrer\">\r\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/itp22final3_261535.jpg\" alt=\"Data\" height=\"5396\" width=\"4090\" title=\"itp22final3_261535\" \/>\r\n\t\t\t\t<\/a>\r\n\t\tTop: down pressure deviation correction, Middle: salinity ratio adjustment, Bottom: Number of filtered spikes\r\n","protected":false},"excerpt":{"rendered":"<p>ITP22 Data Processing The 14 profiles that were recovered from the ITP were processed according to the procedures described in the\u00a0ITP Updated Data Processing Procedures.\u00a0 The processing parameters for ITP 22 are shown in the figures to the right.\u00a0 Despite successful test communications with the profiler on the ice, nothing was heard afterwards from the&hellip;<\/p>\n","protected":false},"author":83,"featured_media":0,"parent":1596,"menu_order":2,"comment_status":"closed","ping_status":"closed","template":"tpl-sidebar.php","meta":{"advanced-sidebar-menu\/link-title":"","advanced-sidebar-menu\/exclude-page":false},"_links":{"self":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/1609"}],"collection":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/users\/83"}],"replies":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/comments?post=1609"}],"version-history":[{"count":3,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/1609\/revisions"}],"predecessor-version":[{"id":3491,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/1609\/revisions\/3491"}],"up":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/1596"}],"wp:attachment":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/media?parent=1609"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}