{"id":2412,"date":"2019-10-23T16:19:58","date_gmt":"2019-10-23T20:19:58","guid":{"rendered":"https:\/\/www2.whoi.edu\/site\/itp\/?page_id=2412"},"modified":"2022-03-23T07:35:36","modified_gmt":"2022-03-23T11:35:36","slug":"itp52-final-data","status":"publish","type":"page","link":"https:\/\/www2.whoi.edu\/site\/itp\/data\/completed-missions\/itp52\/itp52-final-data\/","title":{"rendered":"ITP 052 Final Data"},"content":{"rendered":"\n\n\t<h1>ITP52 Data Description<\/h1>\n\t<p>The ITP profiler was configured to operate on a pattern profiling schedule with different summer and winter schedules.\u00a0 In the summer (between March 1 and October 31), the instrument conducted a 1.5 day repeating pattern of an up profile from 750 to 7 m, followed by 4 one-way (down, up, down, up) profiles between 7 and 200 m, followed by a down profile from 7 to 750 m, all spaced 6 hours apart.\u00a0 In the winter (between November 1 and February 28 or 29), the instrument conducted a 3 day repeating pattern of an up profile from 750 to 7 m, followed 6 hours later by a down profile from 7 to 200 m, followed 24 hours later by an up profile from 200 to 7 m, followed 6 hours later by a down profile from 7 to 750 m, followed by a 36 hour gap before the pattern repeated.\u00a0 The complicate scheme was designed to conserve battery power to extend the lifetime of the instrument, while maximizing the acquisition of the bio-optical data during the summer months.\u00a0 In the surface package, the GPS receiver was powered hourly to obtain locations hourly, and buoy temperature and battery voltage status were recorded.<\/p>\n<p>After circling about a bit, the buoy generally meandered northward along 140\u00b0W during the first month to attain its northernmost location over 150 km north of the deployment site.\u00a0 Thereafter it drifted generally east and south with the Beaufort Gyre circulation. \u00a0The profiler stopped communicating with the surface package after 3.5 months on November 23, 2011.\u00a0 Two months later, the surface package ceased transmitting on January 19, 2012.<\/p>\n<p>The plots to the right are of the final, calibrated, edited data (as opposed to the raw data presented on the active instrument pages).<\/p>\n<p>See the Data Products tab to the left for descriptions of the three levels (I, II, III) of data processing and to access all data.<\/p>\n\n\n\nLevel III 1-db bin-averaged processed profile data in MATLAB format:\u00a0<a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itp52final.mat\">itp52final.mat<\/a><br \/>\nLevel III 1-db bin-averaged processed profile data in ASCII format:\u00a0<a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itp52final.tar.Z\">itp52final.tar.Z<\/a>\u00a0and\u00a0<a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itp52final.zip\">itp52final.zip<\/a>\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp52loc1f_455355.jpg\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp52loc1f_455355.jpg\" alt=\"Plot of buoy locations.\" height=\"1010\" width=\"900\" title=\"itp52loc1f_455355\" \/>\n\t\t\t\t<\/a>\n\t\tPlot of buoy locations.\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp52dat3f_455293.jpg\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp52dat3f_455293.jpg\" alt=\"ITP 52 Temperature and Salinity contours.\" height=\"1570\" width=\"1070\" title=\"itp52dat3f_455293\" \/>\n\t\t\t\t<\/a>\n\t\tITP 52 Temperature and Salinity contours.\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp52dat2f_455259.jpg\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp52dat2f_455259.jpg\" alt=\"Composite plot of ITP temperature and salinity profiles.\" height=\"1300\" width=\"1100\" title=\"itp52dat2f_455259\" \/>\n\t\t\t\t<\/a>\n\t\tComposite plot of ITP temperature and salinity profiles.\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp52dat5f_455243.jpg\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp52dat5f_455243.jpg\" alt=\"ITP 52 dissolved oxygen contours.\" height=\"860\" width=\"1070\" title=\"itp52dat5f_455243\" \/>\n\t\t\t\t<\/a>\n\t\tITP 52 dissolved oxygen contours.\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp52dat4f_455295.jpg\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp52dat4f_455295.jpg\" alt=\"Composite plot of ITP dissolved oxygen profiles.\" height=\"1300\" width=\"600\" title=\"itp52dat4f_455295\" \/>\n\t\t\t\t<\/a>\n\t\tComposite plot of ITP dissolved oxygen profiles.\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp52dat7f_455313.jpg\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp52dat7f_455313.jpg\" alt=\"ITP 52 Turbidity and Chlorophyll a contours.\" height=\"1570\" width=\"1070\" title=\"itp52dat7f_455313\" \/>\n\t\t\t\t<\/a>\n\t\tITP 52 Turbidity and Chlorophyll a contours.\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp52dat6f_455275.jpg\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp52dat6f_455275.jpg\" alt=\"Composite plot of ITP turbidity and chlorophyll a profiles.\" height=\"1300\" width=\"1140\" title=\"itp52dat6f_455275\" \/>\n\t\t\t\t<\/a>\n\t\tComposite plot of ITP turbidity and chlorophyll a profiles.\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp52dat9f_455315.jpg\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp52dat9f_455315.jpg\" alt=\"ITP 52 CDOM and PAR contours.\" height=\"1570\" width=\"1070\" title=\"itp52dat9f_455315\" \/>\n\t\t\t\t<\/a>\n\t\tITP 52 CDOM and PAR contours.\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp52dat8f_455333.jpg\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp52dat8f_455333.jpg\" alt=\"Composite plot of ITP CDOM and PAR profiles.\" height=\"1300\" width=\"1140\" title=\"itp52dat8f_455333\" \/>\n\t\t\t\t<\/a>\n\t\tComposite plot of ITP CDOM and PAR profiles.\n\n","protected":false},"excerpt":{"rendered":"<p>ITP52 Data Description The ITP profiler was configured to operate on a pattern profiling schedule with different summer and winter schedules.\u00a0 In the summer (between March 1 and October 31), the instrument conducted a 1.5 day repeating pattern of an up profile from 750 to 7 m, followed by 4 one-way (down, up, down, up)&hellip;<\/p>\n","protected":false},"author":83,"featured_media":0,"parent":2387,"menu_order":3,"comment_status":"closed","ping_status":"closed","template":"tpl-sidebar.php","meta":{"advanced-sidebar-menu\/link-title":"","advanced-sidebar-menu\/exclude-page":false},"_links":{"self":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/2412"}],"collection":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/users\/83"}],"replies":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/comments?post=2412"}],"version-history":[{"count":4,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/2412\/revisions"}],"predecessor-version":[{"id":4079,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/2412\/revisions\/4079"}],"up":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/2387"}],"wp:attachment":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/media?parent=2412"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}