{"id":2535,"date":"2019-10-24T17:10:43","date_gmt":"2019-10-24T21:10:43","guid":{"rendered":"https:\/\/www2.whoi.edu\/site\/itp\/?page_id=2535"},"modified":"2021-07-20T13:29:15","modified_gmt":"2021-07-20T17:29:15","slug":"itp56-data-processing","status":"publish","type":"page","link":"https:\/\/www2.whoi.edu\/site\/itp\/data\/completed-missions\/itp56\/itp56-data-processing\/","title":{"rendered":"ITP 056 Data Processing"},"content":{"rendered":"\r\n\t<h1>ITP56 Data Processing<\/h1>\r\n\t<p>The 1532 profiles that were recovered from the ITP were processed according to the procedures described in the\u00a0<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/08\/ITP_Data_Processing_Procedures_35803-1.pdf\">ITP Updated Data Processing Procedures<\/a>.\u00a0 The processing parameters for are shown in the figures to the right.\u00a0 Until the buoy reached Fram Strait and broke out of the in early October, there were only a few instances where the drift speed exceeded 30 cm\/s which prevented the profiler from obtaining full profiles.<\/p>\r\n<p>The ITP worked well for the first 200 profiles, but was then struck by either massive obstructions and\/or pump problems. A significant number of the worst conductivity (salinity) profiles were removed. Performance improved somewhat later in the record so that more profiles were retained, but all salinities were marked as questionable (qflag=1) starting with profile 589. Temperature was considered less affected, and was retained throughout.<\/p>\r\n<p>Passing through Fram Strait, the drift speed approached 1 m\/s, and after breaking out of the ice around profile 760, the ITP ceased collecting up profiles. Due to the dense seawater characteristics and roller wear, it is likely that the instrument may have been sliding up the wire towards the top stop after completing the down profile, so that little upward travel distance remained before each up profile.<\/p>\r\n<p>See the Data Products tab to the left for descriptions of the three levels (I, II, III) of data processing and to access all data.<\/p>\r\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp56loc2_481615.jpg\" target=\"_self\" rel=\"noopener noreferrer\">\r\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp56loc2_481615.jpg\" alt=\"ITP Surface Buoy Status\" height=\"1730\" width=\"1000\" title=\"itp56loc2_481615\" \/>\r\n\t\t\t\t<\/a>\r\n\t\tITP Surface Buoy Status\r\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp56dat1_481597.jpg\" target=\"_self\" rel=\"noopener noreferrer\">\r\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp56dat1_481597.jpg\" alt=\"ITP profiler engineering data.\" height=\"1480\" width=\"1560\" title=\"itp56dat1_481597\" \/>\r\n\t\t\t\t<\/a>\r\n\t\tITP profiler engineering data.\r\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp56final1_481653.jpg\" target=\"_self\" rel=\"noopener noreferrer\">\r\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp56final1_481653.jpg\" alt=\"Top: number of bad points removed, Middle: variance of verticle difference of temperature and salinity in step region for up-going profiles, Bottom: temperature lag.\" height=\"5417\" width=\"4086\" title=\"itp56final1_481653\" \/>\r\n\t\t\t\t<\/a>\r\n\t\tTop: number of bad points removed, Middle: variance of verticle difference of temperature and salinity in step region for up-going profiles, Bottom: temperature lag.\r\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp56final2_481635.jpg\" target=\"_self\" rel=\"noopener noreferrer\">\r\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp56final2_481635.jpg\" alt=\"Top: conductivity lag, Middle: conductivity thermal mass amplitude correction, Bottom: conductivity thermal mass lag correction.\" height=\"5424\" width=\"4109\" title=\"itp56final2_481635\" \/>\r\n\t\t\t\t<\/a>\r\n\t\tTop: conductivity lag, Middle: conductivity thermal mass amplitude correction, Bottom: conductivity thermal mass lag correction.\r\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp56final3_481673.jpg\" target=\"_self\" rel=\"noopener noreferrer\">\r\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2019\/10\/itp56final3_481673.jpg\" alt=\"Top: down pressure deviation correction, Middle: salinity ratio adjustment, Bottom: Number of filtered spikes.\" height=\"5409\" width=\"4039\" title=\"itp56final3_481673\" \/>\r\n\t\t\t\t<\/a>\r\n\t\tTop: down pressure deviation correction, Middle: salinity ratio adjustment, Bottom: Number of filtered spikes.\r\n","protected":false},"excerpt":{"rendered":"<p>ITP56 Data Processing The 1532 profiles that were recovered from the ITP were processed according to the procedures described in the\u00a0ITP Updated Data Processing Procedures.\u00a0 The processing parameters for are shown in the figures to the right.\u00a0 Until the buoy reached Fram Strait and broke out of the in early October, there were only a&hellip;<\/p>\n","protected":false},"author":83,"featured_media":0,"parent":2522,"menu_order":2,"comment_status":"closed","ping_status":"closed","template":"tpl-sidebar.php","meta":{"advanced-sidebar-menu\/link-title":"","advanced-sidebar-menu\/exclude-page":false},"_links":{"self":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/2535"}],"collection":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/users\/83"}],"replies":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/comments?post=2535"}],"version-history":[{"count":3,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/2535\/revisions"}],"predecessor-version":[{"id":3614,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/2535\/revisions\/3614"}],"up":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/2522"}],"wp:attachment":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/media?parent=2535"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}