{"id":3978,"date":"2022-03-04T10:21:40","date_gmt":"2022-03-04T14:21:40","guid":{"rendered":"https:\/\/www2.whoi.edu\/site\/itp\/?page_id=3978"},"modified":"2022-03-23T08:05:52","modified_gmt":"2022-03-23T12:05:52","slug":"itp65-final-data","status":"publish","type":"page","link":"https:\/\/www2.whoi.edu\/site\/itp\/data\/completed-missions\/itp65-2\/itp65-final-data\/","title":{"rendered":"ITP 065 Final Data"},"content":{"rendered":"\n\n\t<h1>ITP65 Data Description<\/h1>\n\tThe ITP profiler was configured to operate on a pattern profiling schedule with different summer and winter schedules. In the summer (between deployment and October 31, and after the following March 1), the instrument conducted a 1.5 day repeating pattern of an up profile from 750 to 7 m, followed by 4 one-way (down, up, down, up) profiles between 7 and 200 m, followed by a down profile from 7 to 750 m, all spaced 6 hours apart. In the winter (after November 1), the instrument conducted a 3 day repeating pattern of an up profile from 750 to 7 m, followed 6 hours later by a down profile from 7 to 200 m, followed 24 hours later by an up profile from 200 to 7 m, followed 6 hours later by a down profile from 7 to 750 m, followed by a 36 hour gap before the pattern repeated. The complicated scheme was designed to conserve battery power to extend the lifetime of the instrument, while maximizing the acquisition of the bio-optical data during the summer months. In the surface package, the GPS receiver was powered hourly to obtain locations hourly, and buoy temperature and battery voltage status were recorded.<br \/>\nFor the first 4 months after deployment the ITP generally stayed within a radius of 100 km from where it was deployed, then headed south along 140\u00b0 W, then southwest, and then east over the next 6 months, eventually losing communications with the profiler unexpectedly in deep water. Afterwards the surface package (presumably without mooring) was pushed rapidly west for another 74 days before the surface package ceased transmitting.<br \/>\nThe plots to the right are of the final, calibrated, edited data (as opposed to the raw data presented on the active instrument pages).<br \/>\nSee the Data Products tab to the left for descriptions of the three levels (I, II, III) of data processing and to access all data.\n<p>ITP 65 data can also be found at the links below:<\/p>\n\n\nLevel III 1-db bin-averaged processed profile and SAMI data in MATLAB format: <a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itp65final.mat\">itp65final.mat<\/a><br \/>\nLevel III 1-db bin-averaged processed profile and SAMI data in ASCII format: <a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itp65final.tar.Z\">itp65final.tar.Z<\/a> and <a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itp65final.zip\">itp65final.zip<\/a>\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2022\/03\/itp65loc1f.jpg\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2022\/03\/itp65loc1f.jpg\" alt=\"Plot of buoy locations.\" height=\"1010\" width=\"900\" title=\"itp65loc1f\" \/>\n\t\t\t\t<\/a>\n\t\tPlot of buoy locations.\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2022\/03\/itp65dat3f.jpg\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2022\/03\/itp65dat3f.jpg\" alt=\"ITP 65 Temperature and Salinity contours.\" height=\"1570\" width=\"1070\" title=\"itp65dat3f\" \/>\n\t\t\t\t<\/a>\n\t\tITP 65 Temperature and Salinity contours.\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2022\/03\/itp65dat2f.jpg\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2022\/03\/itp65dat2f.jpg\" alt=\"Composite plot of ITP temperature and salinity profiles.\" height=\"1300\" width=\"1100\" title=\"itp65dat2f\" \/>\n\t\t\t\t<\/a>\n\t\tComposite plot of ITP temperature and salinity profiles.\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2022\/03\/itp65dat5f.jpg\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2022\/03\/itp65dat5f.jpg\" alt=\"ITP 65 dissolved oxygen contours.\" height=\"860\" width=\"1070\" title=\"itp65dat5f\" \/>\n\t\t\t\t<\/a>\n\t\tITP 65 dissolved oxygen contours.\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2022\/03\/itp65dat4f.jpg\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2022\/03\/itp65dat4f.jpg\" alt=\"Composite plot of ITP dissolved oxygen profiles.\" height=\"1300\" width=\"600\" title=\"itp65dat4f\" \/>\n\t\t\t\t<\/a>\n\t\tComposite plot of ITP dissolved oxygen profiles.\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2022\/03\/itp65dat7f.jpg\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2022\/03\/itp65dat7f.jpg\" alt=\"ITP 65 Turbidity and Chlorophyll a contours. \" height=\"1570\" width=\"1070\" title=\"itp65dat7f\" \/>\n\t\t\t\t<\/a>\n\t\tITP 65 Turbidity and Chlorophyll a contours. \n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2022\/03\/itp65dat6f.jpg\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2022\/03\/itp65dat6f.jpg\" alt=\"Composite plot of ITP turbidity and chlorophyll a profiles.\" height=\"1300\" width=\"1140\" title=\"itp65dat6f\" \/>\n\t\t\t\t<\/a>\n\t\tComposite plot of ITP turbidity and chlorophyll a profiles.\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2022\/03\/itp65dat9f.jpg\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2022\/03\/itp65dat9f.jpg\" alt=\"ITP 65 CDOM and PAR contours. \" height=\"1570\" width=\"1070\" title=\"itp65dat9f\" \/>\n\t\t\t\t<\/a>\n\t\tITP 65 CDOM and PAR contours. \n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2022\/03\/itp65dat8f.jpg\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2022\/03\/itp65dat8f.jpg\" alt=\"Composite plot of ITP CDOM and PAR profiles.\" height=\"1300\" width=\"1140\" title=\"itp65dat8f\" \/>\n\t\t\t\t<\/a>\n\t\tComposite plot of ITP CDOM and PAR profiles.\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2022\/03\/itp65dat10f.jpg\" target=\"_self\" rel=\"noopener\">\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2022\/03\/itp65dat10f.jpg\" alt=\"Plot of SAMI time series.\" height=\"1720\" width=\"1000\" title=\"itp65dat10f\" \/>\n\t\t\t\t<\/a>\n\t\tPlot of SAMI time series.\n\n","protected":false},"excerpt":{"rendered":"<p>ITP65 Data Description The ITP profiler was configured to operate on a pattern profiling schedule with different summer and winter schedules. In the summer (between deployment and October 31, and after the following March 1), the instrument conducted a 1.5 day repeating pattern of an up profile from 750 to 7 m, followed by 4&hellip;<\/p>\n","protected":false},"author":99,"featured_media":0,"parent":3942,"menu_order":3,"comment_status":"closed","ping_status":"closed","template":"tpl-sidebar.php","meta":{"advanced-sidebar-menu\/link-title":"","advanced-sidebar-menu\/exclude-page":false},"_links":{"self":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/3978"}],"collection":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/users\/99"}],"replies":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/comments?post=3978"}],"version-history":[{"count":2,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/3978\/revisions"}],"predecessor-version":[{"id":4092,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/3978\/revisions\/4092"}],"up":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/3942"}],"wp:attachment":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/media?parent=3978"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}