{"id":5398,"date":"2024-05-21T15:12:46","date_gmt":"2024-05-21T19:12:46","guid":{"rendered":"https:\/\/www2.whoi.edu\/site\/itp\/?page_id=5398"},"modified":"2024-07-11T10:56:19","modified_gmt":"2024-07-11T14:56:19","slug":"itp93-final-data","status":"publish","type":"page","link":"https:\/\/www2.whoi.edu\/site\/itp\/data\/completed-missions\/itp93-overview\/itp93-final-data\/","title":{"rendered":"ITP 093 Final Data"},"content":{"rendered":"\r\n<h1>ITP 93 Final Data<\/h1>\r\n<p><strong><em>Data Description<\/em><\/strong><\/p>\r\n<p>The ITP profiler was configured to operate on a pattern profiling schedule with different summer and winter schedules.\u00a0 In the summer (between March 1 and October 31), the instrument conducted a 1.5 day repeating pattern of an up profile from 750 to 7 m, followed by 4 one-way (down, up, down, up) profiles between 7 and 200 m, followed by a down profile from 7 to 750 m, all spaced 6 hours apart.\u00a0 In the winter (between November 1 and February 28 or 29), the instrument conducted a 3 day repeating pattern of an up profile from 750 to 7 m, followed 6 hours later by a down profile from 7 to 200 m, followed 24 hours later by an up profile from 200 to 7 m, followed 6 hours later by a down profile from 7 to 750 m, followed by a 36 hour gap before the pattern repeated.\u00a0 The complicate scheme was designed to conserve battery power to extend the lifetime of the instrument, while maximizing the acquisition of the bio-optical data during the summer months.\u00a0 In the surface package, the GPS receiver was powered hourly to obtain locations hourly, and buoy temperature and battery voltage status were recorded.<\/p>\r\n<p>The plots to the right are of the final, calibrated, edited data (as opposed to the raw data presented on the active instrument pages).<\/p>\r\n<p>See the Data Products tab to the left for descriptions of the three levels (I, II, III) of data processing and to access all data.<\/p>\r\n<p><u>ITP 93 data can also be found at the links below:<\/u><\/p>\r\n<p>Level II hourly buoy location data in ASCII format: <a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itpsys93\/itp93rawlocs.dat\">itp93rawlocs.dat<\/a><\/p>\r\n<p>Level III 1-Hz processed profile data in MATLAB format: <a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itpsys93\/itp93cormat.tar.Z\">itp93cormat.tar.Z<\/a> and <a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itpsys93\/itp93cormat.zip\">itp93cormat.zip<\/a><\/p>\r\n<p>Level III 1-db bin-averaged processed profile data in MATLAB format: <a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itpsys93\/itp93final.mat\">itp93final.mat<\/a><br \/>Level III 1-db bin-averaged processed profile data in ASCII format: <a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itpsys93\/itp93final.tar.Z\">itp93final.tar.Z<\/a> and <a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itpsys93\/itp93final.zip\">itp93final.zip<\/a><\/p>\r\n<p><a href=\"https:\/\/www2.whoi.edu\/site\/itp\/data\/completed-missions\/itp93-overview\/itp93-deployment\/\">Deployment<\/a><\/p>\r\n<p><a href=\"https:\/\/www2.whoi.edu\/site\/itp\/data\/completed-missions\/itp93-overview\/itp93-data-processing\/\">Data Processing<\/a><\/p>\r\n<p>&nbsp;<\/p>\r\n<p><a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp93loc1f.jpg\" target=\"_self\" rel=\"noopener\"> <img loading=\"lazy\" title=\"itp93loc1f\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp93loc1f.jpg\" alt=\"Plot of buoy locations.\" width=\"800\" height=\"860\" \/> <\/a> Plot of buoy locations. <a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp93dat3f.jpg\" target=\"_self\" rel=\"noopener\"> <img loading=\"lazy\" title=\"itp93dat3f\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp93dat3f.jpg\" alt=\"ITP 93 Temperature and Salinity contours.\" width=\"1070\" height=\"1570\" \/> <\/a> ITP 93 Temperature and Salinity contours. <a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp93dat2f.jpg\" target=\"_self\" rel=\"noopener\"> <img loading=\"lazy\" title=\"itp93dat2f\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp93dat2f.jpg\" alt=\"Composite plot of ITP temperature and salinity profiles.\" width=\"1100\" height=\"1300\" \/> <\/a> Composite plot of ITP temperature and salinity profiles. <a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp93dat5f.jpg\" target=\"_self\" rel=\"noopener\"> <img loading=\"lazy\" title=\"itp93dat5f\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp93dat5f.jpg\" alt=\"ITP 93 dissolved oxygen contours.\" width=\"1070\" height=\"860\" \/> <\/a> ITP 93 dissolved oxygen contours. <a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp93dat4f.jpg\" target=\"_self\" rel=\"noopener\"> <img loading=\"lazy\" title=\"itp93dat4f\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp93dat4f.jpg\" alt=\"Composite plot of ITP dissolved oxygen profiles.\" width=\"600\" height=\"1300\" \/> <\/a> Composite plot of ITP dissolved oxygen profiles. <a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp93dat7f.jpg\" target=\"_self\" rel=\"noopener\"> <img loading=\"lazy\" title=\"itp93dat7f\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp93dat7f.jpg\" alt=\"ITP 93 Turbidity and Chlorophyll a contours.\" width=\"1070\" height=\"1570\" \/> <\/a> ITP 93 Turbidity and Chlorophyll a contours. <a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp93dat6f.jpg\" target=\"_self\" rel=\"noopener\"> <img loading=\"lazy\" title=\"itp93dat6f\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp93dat6f.jpg\" alt=\"Composite plot of ITP turbidity and chlorophyll a profiles.\" width=\"1140\" height=\"1300\" \/> <\/a> Composite plot of ITP turbidity and chlorophyll a profiles. <a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp93dat9f.jpg\" target=\"_self\" rel=\"noopener\"> <img loading=\"lazy\" title=\"itp93dat9f\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp93dat9f.jpg\" alt=\"ITP 93 CDOM and PAR contours.\" width=\"1070\" height=\"1570\" \/> <\/a> ITP 93 CDOM and PAR contours. <a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp93dat8f.jpg\" target=\"_self\" rel=\"noopener\"> <img loading=\"lazy\" title=\"itp93dat8f\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp93dat8f.jpg\" alt=\"Composite plot of ITP CDOM and PAR profiles.\" width=\"1140\" height=\"1300\" \/> <\/a> Composite plot of ITP CDOM and PAR profiles.<\/p>\r\n","protected":false},"excerpt":{"rendered":"<p>ITP 93 Final Data Data Description The ITP profiler was configured to operate on a pattern profiling schedule with different summer and winter schedules.\u00a0 In the summer (between March 1 and October 31), the instrument conducted a 1.5 day repeating pattern of an up profile from 750 to 7 m, followed by 4 one-way (down,&hellip;<\/p>\n","protected":false},"author":188,"featured_media":0,"parent":5374,"menu_order":3,"comment_status":"closed","ping_status":"closed","template":"tpl-sidebar.php","meta":{"advanced-sidebar-menu\/link-title":"ITP 093 Final Data","advanced-sidebar-menu\/exclude-page":false},"_links":{"self":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/5398"}],"collection":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/users\/188"}],"replies":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/comments?post=5398"}],"version-history":[{"count":3,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/5398\/revisions"}],"predecessor-version":[{"id":5425,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/5398\/revisions\/5425"}],"up":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/5374"}],"wp:attachment":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/media?parent=5398"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}