{"id":5436,"date":"2024-05-23T14:18:37","date_gmt":"2024-05-23T18:18:37","guid":{"rendered":"https:\/\/www2.whoi.edu\/site\/itp\/?page_id=5436"},"modified":"2024-07-11T10:54:58","modified_gmt":"2024-07-11T14:54:58","slug":"itp94-final-data","status":"publish","type":"page","link":"https:\/\/www2.whoi.edu\/site\/itp\/data\/completed-missions\/itp94-overview\/itp94-final-data\/","title":{"rendered":"ITP 094 Final Data"},"content":{"rendered":"\r\n<h1>ITP 94 Final Data<\/h1>\r\n<p><strong><em>Data Description<\/em><\/strong><\/p>\r\n<p>The ITP profiler was configured to operate on a pattern profiling schedule with different summer and winter schedules.\u00a0 In the summer (between March 1 and October 31), the instrument conducted a 1.5 day repeating pattern of an up profile from 750 to 7 m, followed by 4 one-way (down, up, down, up) profiles between 7 and 200 m, followed by a down profile from 7 to 750 m, all spaced 6 hours apart.\u00a0 In the winter (between November 1 and February 28 or 29), the instrument conducted a 3 day repeating pattern of an up profile from 750 to 7 m, followed 6 hours later by a down profile from 7 to 200 m, followed 24 hours later by an up profile from 200 to 7 m, followed 6 hours later by a down profile from 7 to 750 m, followed by a 36 hour gap before the pattern repeated.\u00a0 The complicate scheme was designed to conserve battery power to extend the lifetime of the instrument, while maximizing the acquisition of the bio-optical data during the summer months.\u00a0 In the surface package, the GPS receiver was powered hourly to obtain locations hourly, and buoy temperature and battery voltage status were recorded.<\/p>\r\n<p>The plots to the right are of the final, calibrated, edited data (as opposed to the raw data presented on the active instrument pages).<\/p>\r\n<p>See the Data Products tab to the left for descriptions of the three levels (I, II, III) of data processing and to access all data.<\/p>\r\n<p><u>ITP 94 data can also be found at the links below:<\/u><\/p>\r\n<p>Level II hourly buoy location data in ASCII format: <a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itpsys94\/itp94rawlocs.dat\">itp94rawlocs.dat<\/a><\/p>\r\n<p>Level III 1-Hz processed profile data in MATLAB format: <a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itpsys94\/itp94cormat.tar.Z\">itp94cormat.tar.Z<\/a> and <a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itpsys94\/itp94cormat.zip\">itp94cormat.zip<\/a><\/p>\r\n<p>Level III 1-db bin-averaged processed profile data in MATLAB format: <a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itpsys94\/itp94final.mat\">itp94final.mat<\/a><br \/>Level III 1-db bin-averaged processed profile data in ASCII format: <a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itpsys94\/itp94final.tar.Z\">itp94final.tar.Z<\/a> and <a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itpsys94\/itp94final.zip\">itp94final.zip<\/a><\/p>\r\n<p>Level III 1-db bin-averaged processed profile data in ASCII format: <a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itpsys95\/itp95final.tar.Z\">itp95final.tar.Z<\/a> and <a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itpsys95\/itp95final.zip\">itp95final.zip<\/a><\/p>\r\n<p><a href=\"https:\/\/www2.whoi.edu\/site\/itp\/data\/completed-missions\/itp94-overview\/itp94-deployment\/\">Deployment<\/a><\/p>\r\n<p><a href=\"https:\/\/www2.whoi.edu\/site\/itp\/data\/completed-missions\/itp94-overview\/itp94-data-processing\/\">Data Processing<\/a><\/p>\r\n<p>&nbsp;<\/p>\r\n<p><a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp94loc1f.jpg\" target=\"_self\" rel=\"noopener\"> <img loading=\"lazy\" title=\"itp94loc1f\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp94loc1f.jpg\" alt=\"Plot of buoy locations.\" width=\"810\" height=\"1170\" \/> <\/a> Plot of buoy locations. <a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp94dat3f.jpg\" target=\"_self\" rel=\"noopener\"> <img loading=\"lazy\" title=\"itp94dat3f\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp94dat3f.jpg\" alt=\"ITP 94 Temperature and Salinity contours.\" width=\"1070\" height=\"1570\" \/> <\/a> ITP 94 Temperature and Salinity contours. <a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp94dat2f.jpg\" target=\"_self\" rel=\"noopener\"> <img loading=\"lazy\" title=\"itp94dat2f\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp94dat2f.jpg\" alt=\"Composite plot of ITP temperature and salinity profiles.\" width=\"1100\" height=\"1300\" \/> <\/a> Composite plot of ITP temperature and salinity profiles. <a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp94dat7f.jpg\" target=\"_self\" rel=\"noopener\"> <img loading=\"lazy\" title=\"itp94dat7f\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp94dat7f.jpg\" alt=\"ITP 94 Turbidity and Chlorophyll a contours.\" width=\"1070\" height=\"1570\" \/> <\/a> ITP 94 Turbidity and Chlorophyll a contours. <a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp94dat6f.jpg\" target=\"_self\" rel=\"noopener\"> <img loading=\"lazy\" title=\"itp94dat6f\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp94dat6f.jpg\" alt=\"Composite plot of ITP turbidity and chlorophyll a profiles.\" width=\"1140\" height=\"1300\" \/> <\/a> Composite plot of ITP turbidity and chlorophyll a profiles. <a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp94dat9f.jpg\" target=\"_self\" rel=\"noopener\"> <img loading=\"lazy\" title=\"itp94dat9f\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp94dat9f.jpg\" alt=\"ITP 94 CDOM and PAR contours.\" width=\"1070\" height=\"1570\" \/> <\/a> ITP 94 CDOM and PAR contours. <a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp94dat8f.jpg\" target=\"_self\" rel=\"noopener\"> <img loading=\"lazy\" title=\"itp94dat8f\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/05\/itp94dat8f.jpg\" alt=\"Composite plot of ITP CDOM and PAR profiles.\" width=\"1140\" height=\"1300\" \/> <\/a> Composite plot of ITP CDOM and PAR profiles.<\/p>\r\n","protected":false},"excerpt":{"rendered":"<p>ITP 94 Final Data Data Description The ITP profiler was configured to operate on a pattern profiling schedule with different summer and winter schedules.\u00a0 In the summer (between March 1 and October 31), the instrument conducted a 1.5 day repeating pattern of an up profile from 750 to 7 m, followed by 4 one-way (down,&hellip;<\/p>\n","protected":false},"author":188,"featured_media":0,"parent":5410,"menu_order":3,"comment_status":"closed","ping_status":"closed","template":"tpl-sidebar.php","meta":{"advanced-sidebar-menu\/link-title":"ITP 094 Final Data","advanced-sidebar-menu\/exclude-page":false},"_links":{"self":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/5436"}],"collection":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/users\/188"}],"replies":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/comments?post=5436"}],"version-history":[{"count":3,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/5436\/revisions"}],"predecessor-version":[{"id":5578,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/5436\/revisions\/5578"}],"up":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/5410"}],"wp:attachment":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/media?parent=5436"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}