{"id":5755,"date":"2024-08-15T13:04:23","date_gmt":"2024-08-15T17:04:23","guid":{"rendered":"https:\/\/www2.whoi.edu\/site\/itp\/?page_id=5755"},"modified":"2026-09-10T08:52:58","modified_gmt":"2026-09-10T12:52:58","slug":"itp105-data-processing","status":"publish","type":"page","link":"https:\/\/www2.whoi.edu\/site\/itp\/data\/completed-missions\/itp105-overview\/itp105-data-processing\/","title":{"rendered":"ITP 105 Data Processing"},"content":{"rendered":"\n\n\t<h1>ITP 105 Data Processing<\/h1>\n\t<p>The 6064 profiles that were transmitted from the ITP were processed according to the procedures described in the <a href=\"http:\/\/www.whoi.edu\/fileserver.do?id=35803&amp;pt=2&amp;p=41486\">ITP Updated Data Processing Procedures<\/a>. \u00a0The processing parameters are shown in the figures to the right. The MAVS current probe data is NOT processed to level III due to the uncertainty in profiler heading from magnetic declination measurements.<\/p>\n<p>See the Data Products tab to the left for descriptions of the three levels (I, II, III) of data processing and to access all data.<\/p>\n<p><a href=\"https:\/\/www2.whoi.edu\/site\/itp\/data\/completed-missions\/itp105-overview\/itp105-final-data\/\">Final Data<\/a><\/p>\n<figure>\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/08\/itp105loc2.jpg\" target=\"_self\">\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/08\/itp105loc2.jpg\" alt=\"ITP surface buoy status.\" height=\"1730\" width=\"1000\" title=\"itp105loc2\" loading=\"lazy\" \/>\n\t\t\t\t<\/a>\n\t\t<figcaption>ITP surface buoy status.<\/figcaption>\n\t<\/figure>\n<figure>\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/08\/itp105dat1.jpg\" target=\"_self\">\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/08\/itp105dat1.jpg\" alt=\"ITP profiler engineering data.\" height=\"1480\" width=\"1560\" title=\"itp105dat1\" loading=\"lazy\" \/>\n\t\t\t\t<\/a>\n\t\t<figcaption>ITP profiler engineering data.<\/figcaption>\n\t<\/figure>\n<figure>\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/08\/itp105final1-scaled.jpg\" target=\"_self\">\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/08\/itp105final1-scaled.jpg\" alt=\"Number of bad points removed (top); variance of vertical difference of temperature and salinity in step region for up-going profiles; depth of staircase layer; temperature lag (bottom).\" height=\"2560\" width=\"1978\" title=\"itp105final1\" loading=\"lazy\" \/>\n\t\t\t\t<\/a>\n\t\t<figcaption>Number of bad points removed (top); variance of vertical difference of temperature and salinity in step region for up-going profiles; depth of staircase layer; temperature lag (bottom).<\/figcaption>\n\t<\/figure>\n<figure>\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/08\/itp105final2-scaled.jpg\" target=\"_self\">\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/08\/itp105final2-scaled.jpg\" alt=\"Top: conductivity lag, Middle: conductivity thermal mass amplitude correction, Bottom: conductivity thermal mass lag correction.\" height=\"2560\" width=\"1978\" title=\"itp105final2\" loading=\"lazy\" \/>\n\t\t\t\t<\/a>\n\t\t<figcaption>Top: conductivity lag, Middle: conductivity thermal mass amplitude correction, Bottom: conductivity thermal mass lag correction.<\/figcaption>\n\t<\/figure>\n<figure>\n\t\t\t\t<a href=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/08\/itp105final3-scaled.jpg\" target=\"_self\">\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/08\/itp105final3-scaled.jpg\" alt=\"Top: down pressure deviation correction, Middle: salinity ratio adjustment, Bottom: Number of filtered spikes.\" height=\"2560\" width=\"1978\" title=\"itp105final3\" loading=\"lazy\" \/>\n\t\t\t\t<\/a>\n\t\t<figcaption>Top: down pressure deviation correction, Middle: salinity ratio adjustment, Bottom: Number of filtered spikes.<\/figcaption>\n\t<\/figure>\n\n","protected":false},"excerpt":{"rendered":"<p>ITP 105 Data Processing The 6064 profiles that were transmitted from the ITP were processed according to the procedures described in the ITP Updated Data Processing Procedures. \u00a0The processing parameters are shown in the figures to the right. The MAVS current probe data is NOT processed to level III due to the uncertainty in profiler&hellip;<\/p>\n","protected":false},"author":188,"featured_media":0,"parent":5750,"menu_order":2,"comment_status":"closed","ping_status":"closed","template":"tpl-sidebar.php","meta":{"footnotes":"","_members_access_role":[],"_members_access_error":"","advanced-sidebar-menu\/link-title":"ITP 105 Data Processing","advanced-sidebar-menu\/exclude-page":false},"class_list":["post-5755","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/5755","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/users\/188"}],"replies":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/comments?post=5755"}],"version-history":[{"count":3,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/5755\/revisions"}],"predecessor-version":[{"id":6448,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/5755\/revisions\/6448"}],"up":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/5750"}],"wp:attachment":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/media?parent=5755"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}