{"id":6007,"date":"2024-09-10T11:00:24","date_gmt":"2024-09-10T15:00:24","guid":{"rendered":"https:\/\/www2.whoi.edu\/site\/itp\/?page_id=6007"},"modified":"2024-09-10T11:00:24","modified_gmt":"2024-09-10T15:00:24","slug":"itp113-final-data","status":"publish","type":"page","link":"https:\/\/www2.whoi.edu\/site\/itp\/data\/completed-missions\/itp113-overview\/itp113-final-data\/","title":{"rendered":"ITP 113 Final Data"},"content":{"rendered":"\n\n\t<h1>ITP 113 Final Data<\/h1>\n\t<p>The ITP profiler was configured with a complicated pattern profiling schedule with stationary (at 7 m), shallow (7-250 m) and deep (7-750 m) profiles to maximize the velocity observations.\u00a0 In the surface package, the GPS receiver was powered every 30 minutes to obtain locations, and buoy temperature and battery voltage status were recorded.<\/p>\n<p>The plots to the right are of the final, calibrated, edited data (as opposed to the raw data presented on the active instrument pages).<\/p>\n<p>See the Data Products tab to the left for descriptions of the three levels (I, II, III) of data processing and to access all data.<em><\/em><\/p>\n<p><u>ITP 113 data can also be found at the links below:<\/u><\/p>\n<p>Level II hourly buoy location data in ASCII format: <a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itpsys113\/itp113rawlocs.dat\">itp113rawlocs.dat<\/a><\/p>\n<p>Level III 1-Hz processed profile and microcat data in MATLAB format: <a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itpsys113\/itp113cormat.tar.Z\">itp113cormat.tar.Z<\/a> and <a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itpsys113\/itp113cormat.zip\">itp113cormat.zip<\/a><\/p>\nLevel III 1-db bin-averaged processed profile and microcat data in MATLAB format: <a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itpsys113\/itp113final.mat\">itp113final.mat<\/a><br \/>\nLevel III 1-db bin-averaged processed profile and microcat data in ASCII format: <a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itpsys113\/itp113final.tar.Z\">itp113final.tar.Z<\/a> and <a href=\"https:\/\/scienceweb.whoi.edu\/itp\/data\/itpsys113\/itp113final.zip\">itp113final.zip<\/a>\n<p><a href=\"https:\/\/www2.whoi.edu\/site\/itp\/data\/completed-missions\/itp112-overview\/itp112-deployment\/\">Deployment<\/a><\/p>\n<p><a href=\"https:\/\/www2.whoi.edu\/site\/itp\/data\/completed-missions\/itp112-overview\/itp112-data-processing\/\">Data Processing<\/a><\/p>\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/09\/itp113loc1f.jpg\" alt=\"Plot of buoy locations.\" height=\"1175\" width=\"865\" title=\"itp113loc1f\" \/>\n\t\tPlot of buoy locations.\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/09\/itp113dat3f.jpg\" alt=\"ITP 113 Temperature and Salinity contours.\" height=\"1570\" width=\"1070\" title=\"itp113dat3f\" \/>\n\t\tITP 113 Temperature and Salinity contours.\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/09\/itp113dat2f.jpg\" alt=\"Composite plot of ITP temperature and salinity profiles.\" height=\"1300\" width=\"1100\" title=\"itp113dat2f\" \/>\n\t\tComposite plot of ITP temperature and salinity profiles.\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/09\/itp113dat5f.jpg\" alt=\"ITP 113 East and North velocity contours.\" height=\"1570\" width=\"1070\" title=\"itp113dat5f\" \/>\n\t\tITP 113 East and North velocity contours.\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/09\/itp113dat4f.jpg\" alt=\"Composite plot of East and North velocity profiles.\" height=\"1300\" width=\"1100\" title=\"itp113dat4f\" \/>\n\t\tComposite plot of East and North velocity profiles.\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/09\/itp113dat7f.jpg\" alt=\"Plot of microcat 1 time series.\" height=\"1720\" width=\"1000\" title=\"itp113dat7f\" \/>\n\t\tPlot of microcat 1 time series.\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/09\/itp113dat8f.jpg\" alt=\"Plot of microcat 2 time series.\" height=\"1720\" width=\"1000\" title=\"itp113dat8f\" \/>\n\t\tPlot of microcat 2 time series.\n\n","protected":false},"excerpt":{"rendered":"<p>ITP 113 Final Data The ITP profiler was configured with a complicated pattern profiling schedule with stationary (at 7 m), shallow (7-250 m) and deep (7-750 m) profiles to maximize the velocity observations.\u00a0 In the surface package, the GPS receiver was powered every 30 minutes to obtain locations, and buoy temperature and battery voltage status&hellip;<\/p>\n","protected":false},"author":188,"featured_media":0,"parent":5991,"menu_order":3,"comment_status":"closed","ping_status":"closed","template":"tpl-sidebar.php","meta":{"advanced-sidebar-menu\/link-title":"ITP 113 Final Data","advanced-sidebar-menu\/exclude-page":false},"_links":{"self":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/6007"}],"collection":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/users\/188"}],"replies":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/comments?post=6007"}],"version-history":[{"count":2,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/6007\/revisions"}],"predecessor-version":[{"id":6016,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/6007\/revisions\/6016"}],"up":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/5991"}],"wp:attachment":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/media?parent=6007"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}