{"id":6026,"date":"2024-09-10T11:17:03","date_gmt":"2024-09-10T15:17:03","guid":{"rendered":"https:\/\/www2.whoi.edu\/site\/itp\/?page_id=6026"},"modified":"2024-09-10T11:17:03","modified_gmt":"2024-09-10T15:17:03","slug":"itp114-data-processing","status":"publish","type":"page","link":"https:\/\/www2.whoi.edu\/site\/itp\/data\/completed-missions\/itp114-overview\/itp114-data-processing\/","title":{"rendered":"ITP 114 Data Processing"},"content":{"rendered":"\n\n\t<h1>ITP 114 Data Processing<\/h1>\n\t<p>The 4408 profiles that were transmitted from the ITP were processed according to the procedures described in the <a href=\"http:\/\/www.whoi.edu\/fileserver.do?id=35803&amp;pt=2&amp;p=41486\">ITP Updated Data Processing Procedures<\/a>. \u00a0The processing parameters are shown in the figures to the right.\u00a0 The processing procedures for the MAVS current probe are described in Cole et al. (2015).<\/p>\n<p>See the Data Products tab to the left for descriptions of the three levels (I, II, III) of data processing and to access all data.<\/p>\n<p>References:<\/p>\n<p>Cole, S.T., F.T. Thwaites, R.A. Krishfield, and J.M. Toole, 2015.\u00a0 Processing of velocity Observations from Ice-Tethered Profilers, <em>Proceedings OCEANS&#8217;15 MTS\/IEEE Conference<\/em>, Washington, DC. IEEE Xplore, doi:10.23919\/OCEANS.2015.7401887<\/p>\n<p><a href=\"https:\/\/www2.whoi.edu\/site\/itp\/data\/completed-missions\/itp114-overview\/itp114-deployment\/\">Deployment<\/a><\/p>\n<p><a href=\"https:\/\/www2.whoi.edu\/site\/itp\/data\/completed-missions\/itp114-overview\/itp114-final-data\/\">Final Data<\/a><\/p>\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/09\/itp114loc2.jpg\" alt=\"ITP surface buoy status.\" height=\"1730\" width=\"1000\" title=\"itp114loc2\" \/>\n\t\tITP surface buoy status.\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/09\/itp114dat1.jpg\" alt=\"ITP profiler engineering data.\" height=\"1480\" width=\"1560\" title=\"itp114dat1\" \/>\n\t\tITP profiler engineering data.\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/09\/itp114final1-scaled.jpg\" alt=\"Number of bad points removed (top); variance of vertical difference of temperature and salinity in step region for up-going profiles; depth of staircase layer; temperature lag (bottom).\" height=\"2560\" width=\"1978\" title=\"itp114final1\" \/>\n\t\tNumber of bad points removed (top); variance of vertical difference of temperature and salinity in step region for up-going profiles; depth of staircase layer; temperature lag (bottom).\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/09\/itp114final2-scaled.jpg\" alt=\"Top: conductivity lag, Middle: conductivity thermal mass amplitude correction, Bottom: conductivity thermal mass lag correction.\" height=\"2560\" width=\"1978\" title=\"itp114final2\" \/>\n\t\tTop: conductivity lag, Middle: conductivity thermal mass amplitude correction, Bottom: conductivity thermal mass lag correction.\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/09\/itp114final3-scaled.jpg\" alt=\"Top: down pressure deviation correction, Middle: salinity ratio adjustment, Bottom: Number of filtered spikes.\" height=\"2560\" width=\"1978\" title=\"itp114final3\" \/>\n\t\tTop: down pressure deviation correction, Middle: salinity ratio adjustment, Bottom: Number of filtered spikes.\n\t\t\t\t<img loading=\"lazy\" src=\"https:\/\/www2.whoi.edu\/site\/itp\/wp-content\/uploads\/sites\/92\/2024\/09\/itp114final4-scaled.jpg\" alt=\"Top: Geomagnetic declination correction, Bottom: Correction due to sound speed. \" height=\"2560\" width=\"1978\" title=\"itp114final4\" \/>\n\t\tTop: Geomagnetic declination correction, Bottom: Correction due to sound speed. \n\n","protected":false},"excerpt":{"rendered":"<p>ITP 114 Data Processing The 4408 profiles that were transmitted from the ITP were processed according to the procedures described in the ITP Updated Data Processing Procedures. \u00a0The processing parameters are shown in the figures to the right.\u00a0 The processing procedures for the MAVS current probe are described in Cole et al. (2015). See the&hellip;<\/p>\n","protected":false},"author":188,"featured_media":0,"parent":6018,"menu_order":2,"comment_status":"closed","ping_status":"closed","template":"tpl-sidebar.php","meta":{"advanced-sidebar-menu\/link-title":"ITP 114 Data Processing","advanced-sidebar-menu\/exclude-page":false},"_links":{"self":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/6026"}],"collection":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/users\/188"}],"replies":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/comments?post=6026"}],"version-history":[{"count":2,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/6026\/revisions"}],"predecessor-version":[{"id":6034,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/6026\/revisions\/6034"}],"up":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/pages\/6018"}],"wp:attachment":[{"href":"https:\/\/www2.whoi.edu\/site\/itp\/wp-json\/wp\/v2\/media?parent=6026"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}