{"id":1937,"date":"2022-12-22T13:22:47","date_gmt":"2022-12-22T17:22:47","guid":{"rendered":"https:\/\/wpstaging.whoi.edu\/site\/nosams\/?page_id=1937"},"modified":"2025-05-01T08:20:23","modified_gmt":"2025-05-01T12:20:23","slug":"micadas-gas-interface","status":"publish","type":"page","link":"https:\/\/www2.whoi.edu\/site\/nosams\/sample-requirements\/micadas-gas-interface\/","title":{"rendered":"MICADAS Gas Interface"},"content":{"rendered":"\n\n\t<h1>Sample Requirements for the MICADAS Gas Interface<\/h1>\n<p>Minimum batch size is 20 samples; however, a small number of samples (5-6) may be considered for first time submitters upon <a href=\"mailto:submissions@nosams.whoi.edu?subject=Request%20for%20Introductory%20GIS%20analysis\">request<\/a>. Samples should yield 100-300 \u00b5g C. Samples that produce no reportable result due to carbon yields that are rejected at runtime (far less or exceeding the required range) will incur a fee. Any washing or pre-treatment of the samples must be done prior to submission. When submitting, we recommend that the sample list be ordered from expected oldest to youngest ages, if possible, to minimize the carryover effect during GIS analysis.<\/p>\n<h2>Carbonate minerals by online Carbonate Handling System (CHS)-AMS<\/h2>\n<p>\u03b4<sup>13<\/sup>C by IRMS is not available for samples analyzed using CHS-AMS.<\/p>\n<p>Samples need to be weighed out and submitted in special Exetainer vials provided upon request. Accurate weight is requested.<\/p>\n\n<table id=\"tablepress-10\" class=\"tablepress tablepress-id-10 tablepress-responsive\">\n<thead>\n<tr class=\"row-1 odd\">\n\t<th class=\"column-1\"><\/th><th class=\"column-2\">Typical Sample Size for CHS-&gt; GIS analysis<\/th><th class=\"column-3\">Minimum Batch size<\/th><th class=\"column-4\">Required Carbon mass<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-hover\">\n<tr class=\"row-2 even\">\n\t<td class=\"column-1\"><strong>Carbonate Sample Types<\/strong><\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><p style=\"text-align:left\">20<\/p><\/td><td class=\"column-4\"><p style=\"text-align:left\">100-300 &#181;g C<\/p><\/td>\n<\/tr>\n<tr class=\"row-3 odd\">\n\t<td class=\"column-1\">Foraminifera<\/td><td class=\"column-2\">1-3 milligram<\/td><td class=\"column-3\"><\/td><td class=\"column-4\"><\/td>\n<\/tr>\n<tr class=\"row-4 even\">\n\t<td class=\"column-1\">Coral<\/td><td class=\"column-2\">1-3 milligram<\/td><td class=\"column-3\"><\/td><td class=\"column-4\"><\/td>\n<\/tr>\n<tr class=\"row-5 odd\">\n\t<td class=\"column-1\">Mollusc<\/td><td class=\"column-2\">1-3 milligram<\/td><td class=\"column-3\"><\/td><td class=\"column-4\"><\/td>\n<\/tr>\n<tr class=\"row-6 even\">\n\t<td class=\"column-1\">Otolith<\/td><td class=\"column-2\">1-3 milligram<\/td><td class=\"column-3\"><\/td><td class=\"column-4\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-10 from cache -->\n<p><a name=\"ea-ams\"><\/a><\/p>\n<h2>Organic carbon (ready to burn) by online Elemental Analyzer (EA)-AMS with optional \u03b4<sup>13<\/sup>C<\/h2>\n<p>\u03b4<sup>13<\/sup>C by IRMS is available for samples analyzed using EA-AMS.<\/p>\n<p>Accurate carbon masses are required. Samples must be weighed into tin cups and compressed into a compact spherical or cubic shape with maximum outer dimensions of 6 mm. We recommend using <strong>fresh 5 x 9 mm tin capsules from Costech (code #041077)<\/strong> to match those used internally at NOSAMS. Process blanks for the system have been determined using this capsule and are applied to all results. If using different capsules, please consider submitting a few empty tins so that we can assess the amount of blank carbon in them on the EA (at no charge). Capsules with blank carbon amounts substantially above our internal process blank will be flagged as an alert.<\/p>\n<p>If pre-treated with acid and\/or base, samples should be completely neutralized and dried before weighing them into the tin cups. For encapsulation tips for preparing samples in tin cups, please refer to this <a href=\"https:\/\/stableisotopefacility.ucdavis.edu\/encapsulation-tips-carbon-and-nitrogen-solids\">page<\/a> provided by the UC-Davis Stable Isotope Facility. Polystyrene cell culture plates are recommended for storing and shipping the packed samples in an ordered labelled tray. Adding an index card under the lid may help prevent dislodging during shipping.<\/p>\n\n<table id=\"tablepress-11\" class=\"tablepress tablepress-id-11 tablepress-responsive\">\n<thead>\n<tr class=\"row-1 odd\">\n\t<th class=\"column-1\"><\/th><th class=\"column-2\">Typical Sample Size for EA-&gt; GIS analysis<\/th><th class=\"column-3\">Minimum Batch size<\/th><th class=\"column-4\">Required Carbon mass<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-hover\">\n<tr class=\"row-2 even\">\n\t<td class=\"column-1\"><strong>Organic Carbon Sample Types<\/strong><\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><p style=\"text-align:left\">20<\/p><\/td><td class=\"column-4\"><p style=\"text-align:left\">100-300  &#181;g C<\/p><\/td>\n<\/tr>\n<tr class=\"row-3 odd\">\n\t<td class=\"column-1\">Plant\/Wood<\/td><td class=\"column-2\">0.25 - 0.75 mg<\/td><td class=\"column-3\"><\/td><td class=\"column-4\"><\/td>\n<\/tr>\n<tr class=\"row-4 even\">\n\t<td class=\"column-1\">Sediment (OC)<\/td><td class=\"column-2\">depends on %OC<\/td><td class=\"column-3\"><\/td><td class=\"column-4\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-11 from cache -->\n<p><a name=\"dic-ams\"><\/a><\/p>\n<h2>Dissolved inorganic carbon (DIC) by online headspace-AMS<\/h2>\n<p>\u03b4<sup>13<\/sup>C by IRMS is not available for DIC samples analyzed using headspace-AMS.<\/p>\n<p>Liquid DI<sup>14<\/sup>C samples need to be injected with a syringe by the submitter into specially prepared septum-sealed screw cap Exetainer vials. The vials, provided upon request, are pre-acidified and pre-flushed with helium at NOSAMS, so poisoning with HgCl<sub>2<\/sub> is not necessary. DIC concentration and sample volume are required. The protocol\u00a0for collecting liquid samples into Exetainers is available <a href=\"https:\/\/www2.whoi.edu\/site\/nosams\/wp-content\/uploads\/sites\/124\/2025\/05\/DIC-Sample-Collection-for-Headspace-AMS-2.pdf\">here<\/a>. For more information, please contact <a href=\"https:\/\/www2.whoi.edu\/site\/nosams\/about\/contact\/\">NOSAMS<\/a>.<\/p>\n\n","protected":false},"excerpt":{"rendered":"<p>Sample Requirements for the MICADAS Gas Interface Minimum batch size is 20 samples; however, a small number of samples (5-6) may be considered for first time submitters upon request. Samples should yield 100-300 \u00b5g C. Samples that produce no reportable result due to carbon yields that are rejected at runtime (far less or exceeding the&hellip;<\/p>\n","protected":false},"author":26,"featured_media":0,"parent":1896,"menu_order":2,"comment_status":"closed","ping_status":"closed","template":"tpl-sidebar.php","meta":{"advanced-sidebar-menu\/link-title":"","advanced-sidebar-menu\/exclude-page":false},"_links":{"self":[{"href":"https:\/\/www2.whoi.edu\/site\/nosams\/wp-json\/wp\/v2\/pages\/1937"}],"collection":[{"href":"https:\/\/www2.whoi.edu\/site\/nosams\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www2.whoi.edu\/site\/nosams\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/nosams\/wp-json\/wp\/v2\/users\/26"}],"replies":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/nosams\/wp-json\/wp\/v2\/comments?post=1937"}],"version-history":[{"count":3,"href":"https:\/\/www2.whoi.edu\/site\/nosams\/wp-json\/wp\/v2\/pages\/1937\/revisions"}],"predecessor-version":[{"id":2836,"href":"https:\/\/www2.whoi.edu\/site\/nosams\/wp-json\/wp\/v2\/pages\/1937\/revisions\/2836"}],"up":[{"embeddable":true,"href":"https:\/\/www2.whoi.edu\/site\/nosams\/wp-json\/wp\/v2\/pages\/1896"}],"wp:attachment":[{"href":"https:\/\/www2.whoi.edu\/site\/nosams\/wp-json\/wp\/v2\/media?parent=1937"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}